Vis enkel innførsel

dc.contributor.authorL'Abée-Lund, Jan Henning
dc.contributor.authorVillar, Jaime Otero
dc.coverage.spatialNorwaynb_NO
dc.date.accessioned2018-03-06T10:06:16Z
dc.date.available2018-03-06T10:06:16Z
dc.date.issued2017
dc.identifier.isbn978-82-410-1559-5
dc.identifier.issn1501-2832
dc.identifier.urihttp://hdl.handle.net/11250/2488830
dc.description.abstractStart-stop practice was analysed in 256 Norwegian hydropower plants in conjunction to a set of characteristics. The plants were on grid 2005 - 2014, and production data from 2015. Number of starts were counted for each plant finding a higher number in Kaplan turbines than in Francis and Pelton. Number of starts was not dependent on having a license to practice start-stop, and were related to the annual mean river discharge being negative for Francis, dome-shaped for Pelton, and no association for Kaplan.nb_NO
dc.language.isonobnb_NO
dc.publisherNVEnb_NO
dc.relation.ispartofseriesNVE Rapport;2017:9
dc.subjectNedbørnb_NO
dc.subjectSmåkraftverknb_NO
dc.subjectTurbinernb_NO
dc.subjectVannføringnb_NO
dc.titleStart-stop practice in small Norwegian hydropower plantsnb_NO
dc.typeResearch reportnb_NO
dc.source.pagenumber38nb_NO